Table of Parameters for Steel-Core Aluminum Conductors and Steel Strands with Compression Connectors
Release time:
2025-07-23
Steel Strand Specifications: Steel Strand Outer Diameter (mm) | Compression Connector Dimensions: Outer Diameter × Length (mm) GJ-35 | 7.8 | 16×220 GJ-50 | 9 | 18×240 GJ-55 | 9.6 | 22×240 GJ-70 | 11 | 22×290 GJ-80 | 11.5 | 24×290 GJ-100 | 13 | 26×340 GJ-120 | 14 | 28×380 GJ-135 | 15 | 30×400 GJ-150 | 16 | 32×430 Aluminum-Conductor Steel-Reinforced (ACSR) Compression Connector Dimensions: Aluminum Tube Outer Diameter × Length (mm) | Steel Tube Outer Diameter (mm) LGJ-240/30 | 36×450 | 2
Steel strand specifications | Steel strand outer diameter (mm) | Crimping connector dimensions: outer diameter × length (mm) |
GJ-35 | 7.8 | 16×220 |
GJ-50 | 9 | 18 × 240 |
GJ-55 | 9.6 | 22 × 240 |
GJ-70 | 11 | 22 × 290 |
GJ-80 | 11.5 | 24 × 290 |
GJ-100 | 13 | 26 × 340 |
GJ-120 | 14 | 28 × 380 |
GJ-135 | 15 | 30×400 |
GJ-150 | 16 | 32 × 430 |
Aluminum Stranded Wire Specifications | Outer diameter of aluminum stranded wire (mm) | Crimping connector dimensions: outer diameter × length (mm) |
LJ-150 | 15.75 | 30×280 |
LJ-185 | 17.5 | 32 × 310 |
LJ-210 | 18.75 | 34 × 330 |
LJ-240 | 20 | 36 × 350 |
LJ-300 | 22.4 | 40 × 390 |
LJ-400 | 25.9 | 45 × 450 |
LJ-500 | 29.12 | 52 × 510 |
LJ-630 | 32.67 | 60 × 570 |
LJ-800 | 36.9 | 65 × 650 |
Specifications for Good-Conductivity Ground Wires | Crimping connector dimensions | |
Aluminum tube Outer diameter × Length (mm) | Steel pipe outer diameter (mm) | |
LGJ-50/30 | 26 × 340 | 14 |
LGJ-70/40 | 32 × 400 | 18 |
LGJ-95/55 | 34 × 470 | 20 |
LGJ-95/140 | 45 × 685 | 30 |
LGJ-120/70 | 36 × 510 | 22 |
Overhead insulated wire specifications | Conductor outer diameter (mm) | Crimping connector dimensions: outer diameter × length (mm) |
JKLYJ-35 | 7 | 20×130 |
JKLYJ-50 | 8.3 | 20×140 |
JKLYJ-70 | 10 | 22 × 170 |
JKLYJ-95 | 11.6 | 24 × 190 |
JKLYJ-120 | 13 | 26 × 210 |
JKLYJ-150 | 14.6 | 28 × 240 |
JKLYJ-185 | 16.2 | 32 × 260 |
JKLYJ-240 | 18.4 | 34 × 290 |
Steel-core aluminum stranded wire | Crimping connector dimensions | |
Aluminum tube Outer diameter × Length (mm) | Steel pipe outer diameter (mm) | |
LGJ-240/30 | 36 × 450 | 20 |
LGJ-240/40 | 36 × 470 | 20 |
LGJ-240/55 | 36 × 490 | 22 |
LGJ-300/15 | 40×440 | 18 |
LGJ-300/20 | 40 × 450 | 18 |
LGJ-300/25 | 40×480 | 20 |
LGJ-300/40 | 40 × 490 | 20 |
LGJ-300/50 | 40×510 | 22 |
LGJ-300/70 | 42 × 560 | 24 |
LGJ-400/20 | 45 × 570 | 18 |
LGJ-400/25 | 45 × 520 | 20 |
LGJ-400/35 | 45 × 540 | 22 |
LGJ-400/50 | 45 × 570 | 24 |
LGJ-400/65 | 48 × 580 | 26 |
LGJ-500/35 | 52 × 580 | 22 |
LGJ-500/45 | 52 × 610 | 24 |
LGJ-500/65 | 52 × 640 | 26 |
LGJ-630/45 | 60 × 650 | 24 |
LGJ-630/55 | 60 × 680 | 26 |
LGJ-720/50 | 60 × 710 | 24 |
LGJ-800/55 | 65 × 730 | 26 |
LGJ-800/70 | 65 × 760 | 26 |
Note: Refer to DL/T758-2001 for splicing fittings.
Substation Conductor Specifications | Outer diameter (mm) of compression fitting for tension clamp | |
LGKK-600 | 51 | 76 |
LGKK-900 | 59 | 74 |
LGJQT-1400 | 51 | 76 |
NAHLGJQ-1440 | 80 |
Steel strand specifications | Steel strand outer diameter (mm) | Crimping connector dimensions: outer diameter × length (mm) |
GJ-35 | 7.8 | 16×220 |
GJ-50 | 9 | 18 × 240 |
GJ-55 | 9.6 | 22 × 240 |
GJ-70 | 11 | 22 × 290 |
GJ-80 | 11.5 | 24 × 290 |
GJ-100 | 13 | 26 × 340 |
GJ-120 | 14 | 28 × 380 |
GJ-135 | 15 | 30×400 |
GJ-150 | 16 | 32 × 430 |
Aluminum Stranded Wire Specifications | Outer diameter of aluminum stranded wire (mm) | Crimping connector dimensions: outer diameter × length (mm) |
LJ-150 | 15.75 | 30×280 |
LJ-185 | 17.5 | 32 × 310 |
LJ-210 | 18.75 | 34 × 330 |
LJ-240 | 20 | 36 × 350 |
LJ-300 | 22.4 | 40 × 390 |
LJ-400 | 25.9 | 45 × 450 |
LJ-500 | 29.12 | 52 × 510 |
LJ-630 | 32.67 | 60 × 570 |
LJ-800 | 36.9 | 65 × 650 |
Specifications for Good-Conductivity Ground Wires | Crimping connector dimensions | |
Aluminum tube Outer diameter × Length (mm) | Steel pipe outer diameter (mm) | |
LGJ-50/30 | 26 × 340 | 14 |
LGJ-70/40 | 32 × 400 | 18 |
LGJ-95/55 | 34 × 470 | 20 |
LGJ-95/140 | 45 × 685 | 30 |
LGJ-120/70 | 36 × 510 | 22 |
Steel-core aluminum stranded wire | Crimping connector dimensions | |
Aluminum tube Outer diameter × Length (mm) | Steel pipe outer diameter (mm) | |
LGJ-240/30 | 36 × 450 | 20 |
LGJ-240/40 | 36 × 470 | 20 |
LGJ-240/55 | 36 × 490 | 22 |
LGJ-300/15 | 40×440 | 18 |
LGJ-300/20 | 40 × 450 | 18 |
LGJ-300/25 | 40×480 | 20 |
LGJ-300/40 | 40 × 490 | 20 |
LGJ-300/50 | 40×510 | 22 |
LGJ-300/70 | 42 × 560 | 24 |
LGJ-400/20 | 45 × 570 | 18 |
LGJ-400/25 | 45 × 520 | 20 |
LGJ-400/35 | 45 × 540 | 22 |
LGJ-400/50 | 45 × 570 | 24 |
LGJ-400/65 | 48 × 580 | 26 |
LGJ-500/35 | 52 × 580 | 22 |
LGJ-500/45 | 52 × 610 | 24 |
LGJ-500/65 | 52 × 640 | 26 |
LGJ-630/45 | 60 × 650 | 24 |
LGJ-630/55 | 60 × 680 | 26 |
LGJ-720/50 | 60 × 710 | 24 |
LGJ-800/55 | 65 × 730 | 26 |
LGJ-800/70 | 65 × 760 | 26 |
Note: Refer to DL/T758-2001 for splicing fittings.
Substation Conductor Specifications | Outer diameter (mm) of compression fitting for tension clamp | |
LGKK-600 | 51 | 76 |
LGKK-900 | 59 | 74 |
LGJQT-1400 | 51 | 76 |
NAHLGJQ-1440 | 80 |
Overhead insulated wire specifications | Conductor outer diameter (mm) | Crimping connector dimensions: outer diameter × length (mm) |
JKLYJ-35 | 7 | 20×130 |
JKLYJ-50 | 8.3 | 20×140 |
JKLYJ-70 | 10 | 22 × 170 |
JKLYJ-95 | 11.6 | 24 × 190 |
JKLYJ-120 | 13 | 26 × 210 |
JKLYJ-150 | 14.6 | 28 × 240 |
JKLYJ-185 | 16.2 | 32 × 260 |
JKLYJ-240 | 18.4 | 34 × 290 |
Tags: